Valeo showcases advanced liquid cooling solutions for AI data centres

Valeo has introduced its aluminium Rear Door Cooling Module (RDHx) alongside its range of liquid cooling solutions. The showcase features technologies designed to address the increasing cooling demands of AI workloads and high-performance computing systems.

As AI applications drive higher chip thermal design power and rack power densities, conventional air-cooling systems face growing limitations. Drawing on its automotive thermal engineering and manufacturing capabilities, Valeo is presenting solutions designed to support data centre operators in improving cooling efficiency and managing energy consumption.

The newly unveiled aluminium Rear Door Cooling Module offers a 38 per cent increase in cooling capacity and a 65 per cent improvement in power density compared with conventional copper equivalents. Designed for high-density racks and fan wall applications across different rack sizes, the module also reduces electrical fan consumption by 25 per cent. Its proprietary surface coating is intended to provide long-term durability, while the solution supports both new data centre facilities and infrastructure upgrades.

Commenting on the launch, Pascale Herman, Vice President, Data Centers & BESS at Valeo, said: “We are proud to present our aluminum heat exchanger cooling module technology for the first time at Data Centre World Paris. Data centers today are caught between increasing AI compute densities and strict energy targets. Whether facilities are looking to upgrade existing racks or architect next-generation AI clusters from the ground up, Valeo’s offers a large portfolio of practical, scalable tools to cut power usage and sustainably while maximizing compute capacity.”

Alongside the RDHx module, Valeo is showcasing single-phase and two-phase Direct-to-Chip (DtC) cold plates for CPUs and GPUs. These solutions use a multi-material architecture and a casing saddle assembly process designed to minimise copper usage and improve leak resistance. Their internal heat exchange design can dissipate heat fluxes of up to 200 W/cm² while optimising pump mass flow.

The company is also presenting its Cooling Distribution Units (CDUs) and rack manifolds for single-phase and two-phase applications. Built to automotive quality standards, these systems include hot-swappable pumps, brazed junctions, failure prediction controls and predictive maintenance software.

Valeo is further demonstrating a passive two-phase Direct-to-Chip cooling system developed in partnership with Calyos. Based on Loop Heat Pipe (LHP) technology, the system uses capillary and gravity action instead of mechanical liquid pumps. It offers 27 per cent higher cooling capacity compared with air cooling and reduces fan energy consumption by 40 per cent. The solution is designed for air-cooled CPU racks used in inference workloads and edge computing applications.